Published 2023 | Version v1
Journal article

The use of CCCM for the creation of the high-temperature detectors of the water vapor

  • 1. National Science Center "Kharkov Institute of Physics and Technology" Kharkiv (Ukraine)
  • 2. Kharkiv National University of Radio Electronics, Kharkiv (Ukraine)
  • 3. National Science Center "Kharkov Institute of Physics and Technology", Kharkiv (Ukraine)

Description

A technique for assessing the presence of water vapor in a mixture using high-temperature detectors made of carbon-carbon composite material (CCCM) is proposed. The change in the electrical resistance of CCCM in a mixture containing water vapor at a temperature of 1000 °C is presented. The efficiency of such detectors has been tested and experimentally confirmed. (author)

Additional details

Publishing Information

Journal Title
Voprosy Atomnoj Nauki i Tekhniki
Journal Issue
no.2-144
Journal Page Range
p. 140-142
ISSN
1562-6016