Published October 1981
| Version v1
Journal article
Heat exchanger applications during TMI-2 post accident cooldown
Description
The Decay Heat Removal System was not used to remove decay heat following the accident at Three Mile Island Unit 2. Instead, other systems were utilized. Further, additional systems were designed to provide supplementary post-accident heat removal capability. Still other backup systems were designed, but not installed. This paper discusses post-accident cooldown, as well as means taken to provide backup cooling capability. The TMI-2 post-accident experience clearly demonstrates the wide range of options available for removing decay heat
Additional details
Publishing Information
- Journal Title
- Am. Soc. Mech. Eng., [Pap.]
- Journal Issue
- 81-jpgc-ne-9
- Series
- Am. Soc. Mech. Eng., [Pap.].
- ISSN
- 0402-1215
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13689241
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- AFTER-HEAT REMOVAL; HEAT EXCHANGERS; NUCLEAR POWER PLANTS; REACTOR COOLING SYSTEMS; REACTOR SAFETY; STEAM GENERATORS; THREE MILE ISLAND-2 REACTOR
- Descriptors DEC
- BOILERS; COOLING SYSTEMS; ENRICHED URANIUM REACTORS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTOR COMPONENTS; REACTORS; SAFETY; THERMAL POWER PLANTS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS