Preparation of Radio-pharmaceuticals-III: An evaluation of the eluate from a 113Sn-113mIn cow system

  • 1. Korea Atomic Research Institue, Seoul (Korea, Republic of)

Description

In 1968 total 94,660 mc of radioactive iodocompound were prepared and distributed to the urers. In order to obtain an effective liver scanning 113mIncolloidal of even partical size from a 113Sn-113mIn cow, the eluate(pH; 1.5) was examined by a radio paper partition chromatography. It was found that the eluate was composed of two components, ionic from and colloidal form. The ionid from could be eliminated by cation exchange resine and the eluate from the ion exchange resine was of even particle size to give an excellent liver scanning results. Labelling of 113mIn to human serum albumine was attempted.

Additional details

Publishing Information

Journal Title
Korean Journal of Nuclear Medicine
Journal Volume
3
Journal Issue
1
Series
8 refs, 3 figs, 1 tab
Journal Page Range
p. 69-72