Construction of Chinese adult male phantom library and its application in the virtual calibration of in vivo measurement
- 1. Department of Engineering Physics, Tsinghua University, Beijing 100084 (China)
Description
In vivo measurement is a main method of internal contamination evaluation, particularly for large numbers of people after a nuclear accident. Before the practical application, it is necessary to obtain the counting efficiency of the detector by calibration. The virtual calibration based on Monte Carlo simulation usually uses the reference human computational phantom, and the morphological difference between the monitored personnel with the calibrated phantom may lead to the deviation of the counting efficiency. Therefore, a phantom library containing a wide range of heights and total body masses is needed. In this study, a Chinese reference adult male polygon surface (CRAM-S) phantom was constructed based on the CRAM voxel phantom, with the organ models adjusted to match the Chinese reference data. CRAM-S phantom was then transformed to sitting posture for convenience in practical monitoring. Referring to the mass and height distribution of the Chinese adult male, a phantom library containing 84 phantoms was constructed by deforming the reference surface phantom. Phantoms in the library have 7 different heights ranging from 155 cm to 185 cm, and there are 12 phantoms with different total body masses in each height. As an example of application, organ specific and total counting efficiencies of Ba-133 were calculated using the MCNPX code, with two series of phantoms selected from the library. The influence of morphological variation on the counting efficiency was analyzed. The results show only using the reference phantom in virtual calibration may lead to an error of 68.9% for total counting efficiency. Thus the influence of morphological difference on virtual calibration can be greatly reduced using the phantom library with a wide range of masses and heights instead of a single reference phantom. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/61/5/2124Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 61
- Journal Issue
- 5
- Journal Page Range
- p. 2124-2144
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47107472
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BARIUM 133; CALIBRATION; CHINA; COMPUTERIZED SIMULATION; EFFICIENCY; IN VIVO; MONTE CARLO METHOD; PHANTOMS; RADIATION ACCIDENTS; RADIATION MONITORS; RADIONUCLIDE KINETICS; REACTOR ACCIDENTS
- Descriptors DEC
- ACCIDENTS; ALKALINE EARTH ISOTOPES; ASIA; BARIUM ISOTOPES; BETA DECAY RADIOISOTOPES; CALCULATION METHODS; DAYS LIVING RADIOISOTOPES; ELECTRON CAPTURE RADIOISOTOPES; EVEN-ODD NUCLEI; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; KINETICS; MEASURING INSTRUMENTS; MOCKUP; MONITORS; NUCLEI; RADIOISOTOPES; SIMULATION; STRUCTURAL MODELS; YEARS LIVING RADIOISOTOPES