Published March 1992 | Version v1
Journal article

Steam generator design of 200 MW modular HTGR

  • 1. Xi'an Jiaotong Univ. (China)

Description

A design of steam generator, the key component of 200 MW modular HTGR (High Temperature Gas-cooled Reactor), with helium inlet temperature 700 C degree, helium pressure 5.89 MPa, steam temperature 530 C degree and pressure 16.67 MPa is presented. The steam generator has a structure of upward flow and once-through multi-head coil tubes. The detail structure of coil tubes and other parts are described, and the results of design calculation as well

Additional details

Publishing Information

Journal Title
Chinese Journal of Nuclear Science and Engineering
Journal Volume
12
Journal Issue
1
Journal Page Range
p. 25-34.
ISSN
0258-0918
CODEN
HYGODG