Published 1984 | Version v1
Report Open

Heat transfer decreasing in a tube for up and down water flow

Description

The experimental data on temperature conditions of the uniformly heated vertical tube of 9.75 mm internal diameter in case of water boiling in it under the up and down flow conditions are presented. The experiments have been conducted at pressures of 9.8-17.8 MPa, mass rates 350-1500 kg/(m2s) and specific heat fluxes-100-800 kW/m2. At 9.8 MPa critical steam contents, temperature fields and heat transfer coefficients in the post burnout zone are independent of the flow direction. While pressure growing the differences in temperature conditions at various flow directions increase, they decrease with the mass rate increase. At high pressures the heat transfer coefficients decrease with the heat flux increase

Availability note (English)

MF available from INIS under the Report Number.

Files

16034826.pdf

Files (485.8 kB)

Name Size Download all
md5:97546152eb2c9ed6f89d1d6ee3586d9c
485.8 kB Preview Download

System files (30.4 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Исследование ухудшения теплоотдачи при подьемном и опускном течении воды в трубе

Publishing Information

Imprint Pagination
18 p.
Report number
FEI--1539

Optional Information

Notes
7 refs.; 7 figs.