Published August 21, 2016 | Version v1
Journal article

Anomalous effects on radiation detectors and capacitance measurements inside a modified Faraday cage

  • 1. Institute for Industrial, Radiophysical and Environmental Safety, Universitat Politècnica de València, Camino de Vera, s/n, Valencia (Spain)
  • 2. Traffic Control Systems Group, ITACA Institute, Universitat Politécnica de, Camino de Vera, s/n, Valencia (Spain)
  • 3. Centre de Physique Théorique, CNRS, École Polytechnique, F-91128 Palaiseau (France)
  • 4. Institute of Theoretical and Experimental Biophysics, Russian Academy of Science, Moscow Region, Pushchino 142290 (Russian Federation)
  • 5. Chemical and Nuclear Engineering Department, Universitat Politécnica de Valencia, Camino de Vera, s/n, Valencia (Spain)

Description

We present experimental results showing certain anomalies in the measurements performed inside a modified Faraday cage of decay rates of Ra-226, Tl-204 and Sr-90/I-90, of the gamma spectrum of a Cs-137 preparation, and of the capacitance of both a class-I multilayer ceramic capacitor and of the interconnection cable between the radiation detector and the scaler. Decay rates fluctuate significantly up to 5% around the initial value and differently depending on the type of nuclide, and the spectrum photopeak increases in 4.4%. In the case of the capacitor, direct capacitance measurements at 100 Hz, 10 kHz and 100 kHz show variations up to 0.7%, the most significant taking place at 100 Hz. In the case of the interconnection cable, the capacitance varies up to 1%. Dispersion also tends to increase inside the enclosure. However, the measured capacitance variations do not explain the variations observed in decay rates. - Highlights: • Background counts and decay rates changes of different nuclides are described. • Those changes are observed inside a multilayer modified Faraday cage. • Noise in a multichannel analyzer increases inside the multilayer enclosure. • Capacitance of a class-I multilayer ceramic capacitor varies inside the enclosure. • Capacitance changes depend on the used frequency.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2016.05.051

Additional details

Identifiers

DOI
10.1016/j.nima.2016.05.051;
PII
S0168-9002(16)30440-5;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
828
Journal Page Range
p. 210-228
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright