High dose gamma-ray standard
Creators
- 1. Horia Hulubei National Institute for Physics and Nuclear Engineering, PO Box MG-6, RO-76900 Magurele-Bucharest (Romania)
Description
The high gamma-ray doses produced in a gamma irradiator are used, mainly, for radiation processing, i.e. sterilization of medical products, processing of food, modifications of polymers, irradiation of electronic devices, a.s.o. The used absorbed doses are depending on the application and are covering the range between 10 Gy and 100 MGy. The regulations in our country require that the response of the dosimetry systems, used for the irradiation of food and medical products, be calibrated and traceable to the national standards. In order to be sure that the products receive the desired absorbed dose, appropriate dosimetric measurements must be performed, including the calibration of the dosemeters and their traceability to the national standards. The high dose gamma-ray measurements are predominantly based on the use of reference radiochemical dosemeters. Among them the ferrous sulfate can be used as reference dosemeter for low doses (up to 400 Gy) but due to its characteristics it deserves to be considered a standard dosemeter and to be used for transferring the conventional absorbed dose to other chemical dosemeters used for absorbed doses up to 100 MGy. The study of the ferrous sulfate dosemeter consisted in preparing many batches of solution by different operators in quality assurance conditions and in determining for all batches the linearity, the relative intrinsic error, the repeatability and the reproducibility. The principal results are the following: the linear regression coefficient - 0.999, the relative intrinsic error - max.6%, the repeatability (for P*=95%) - max.3%, the reproducibility (P*=95%) - max.5%
Availability note (English)
Available from author(s) or Office of Documentation, Publication and Printing, Horia Hulubei National Institute for Physics and Nuclear Engineering, PO Box MG-6, RO-76900 -Bucharest-Magurele (RO)Additional details
Publishing Information
- Imprint Title
- IFIN-HH, Scientific Report 1999
- Imprint Pagination
- 175 p.
- Journal Page Range
- p. 141
- ISSN
- 1454-2714
- Report number
- IFIN-HH-AR--2000
INIS
- Country of Publication
- Romania
- Country of Input or Organization
- Romania
- INIS RN
- 32005615
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Non-conventional Literature, Progress Report
- Descriptors DEI
- CALIBRATION STANDARDS; CHEMICAL DOSEMETERS; GAMMA RADIATION; IRRADIATION PROCEDURES; PROGRESS REPORT; RADIATION DOSES
- Descriptors DEC
- DOCUMENT TYPES; DOSEMETERS; DOSES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; RADIATIONS; STANDARDS
Optional Information
- Notes
- Short communication. 1 ref.