Design of a coincidence processing board for a dual-head PET scanner for breast imaging
Creators
- 1. Departamento de Ingenieria Electronica, University Politecnica de Valencia, Camino de Vera s/n 46022, Valencia (Spain)
- 2. Instituto de Fisica Corpuscular, CSIC-UV, Valencia (Spain)
Description
This paper describes the design of a coincidence processing board for a dual-head Positron Emission Tomography (PET) scanner for breast imaging. The proposed block-oriented data acquisition system relies on a high-speed DSP processor for fully digital trigger and on-line event processing that surpasses the performance of traditional analog coincidence detection systems. A mixed-signal board has been designed and manufactured. The analog section comprises 12 coaxial inputs (six per head) which are digitized by means of two 8-channel 12-bit 40-MHz ADCs in order to acquire the scintillation pulse, the charge division signals and the depth of interaction within the scintillator. At the digital section, a state-of-the-art FPGA is used as deserializer and also implements the DMA interface to the DSP processor by storing each digitized channel into a fast embedded FIFO memory. The system incorporates a high-speed USB 2.0 interface to the host computer
Additional details
Identifiers
- DOI
- 10.1016/j.nima.2005.03.018;
- PII
- S0168-9002(05)00631-5;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 546
- Journal Issue
- 1-2
- Journal Page Range
- p. 28-32
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 6. international workshop on radiation imaging detectors
- Dates
- 25-29 Jul 2004
- Place
- Glasgow (United Kingdom)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 37040011
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ANALOG-TO-DIGITAL CONVERTERS; BIOMEDICAL RADIOGRAPHY; DATA ACQUISITION; DATA ACQUISITION SYSTEMS; DESIGN; INTERFACES; MAMMARY GLANDS; MHZ RANGE 01-100; PERFORMANCE; POSITRON COMPUTED TOMOGRAPHY; SIGNALS; VELOCITY
- Descriptors DEC
- BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; ELECTRONIC EQUIPMENT; EMISSION COMPUTED TOMOGRAPHY; EQUIPMENT; FREQUENCY RANGE; GLANDS; MEDICINE; MHZ RANGE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2005 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.