Dose assessment on temperature monitoring units in Indus-2 tunnel

  • 1. Bhabha Atomic Research Centre, Mumbai (India)
  • 2. Raja Ramanna Centre for Advanced Technology, Indore (India)

Description

Temperature Monitoring Units (TMUs) are installed in Indus-2 storage ring tunnel to measure the temperature on dipole vacuum chamber. Erroneous reading from the TMUs was reported and suspected that radiation damage may be causing the malfunctioning. In order to ascertain the malfunctioning due to radiation damage, a dose assessment on the TMU and nearby locations were performed using CaSO4: Dy thermo-luminescence (TL) discs. Before the measurement, TL discs were annealed and exposed to 60Co radiation for known dose and discs within ±10% were selected for the measurement. The measurement was carried out for 10 days at the TMU locations and surrounding areas which covered total of 12 locations. The results indicate that radiation damage is probable cause of malfunctioning as the projected dose over an year, based on the measurement, is found to cross the damage threshold. The paper describes the details of the measurement and results. (author)

Part of:
Proceedings of the eighth DAE-BRNS Indian particle accelerator conference

Additional details

Publishing Information

Publisher
Raja Ramanna Centre for Advanced Technology
Imprint Place
Indore (India)
Imprint Title
Proceedings of the eighth DAE-BRNS Indian particle accelerator conference
Imprint Pagination
1194 p.
Journal Page Range
p. 538-540

Conference

Title
8. DAE-BRNS Indian particle accelerator conference
Acronym
InPAC-2018
Dates
9-12 Jan 2018
Place
Indore (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
49078305
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM CURRENTS; GLOW CURVE; INDUS-2; RADIATION DOSES; RADIATION MONITORING; TEMPERATURE MEASUREMENT
Descriptors DEC
CURRENTS; DOSES; MONITORING; RADIATION SOURCES; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES

Optional Information

Notes
3 refs., 3 figs., 1 tab.