Published June 1977 | Version v1
Journal article

Intensity and position measuring systems in the booster of the Zero Gradient Synchrotron

  • 1. Argonne National Lab., IL

Description

Soon the new booster for the Zero Gradient Synchrotron (ZGS) will be commissioned at Argonne. Three of its diagnostic systems are described: (1) the beam position system; (2) the toroid intensity measuring system; and (3) the capacitive intensity measuring system

Additional details

Identifiers

Publishing Information

Journal Title
IEEE Transactions on Nuclear Science
Journal Volume
24
Journal Issue
3
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
1739-1741
ISSN
0018-9499

Conference

Title
Particle accelerator conference.
Dates
16 Mar 1977.
Place
Chicago, IL, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
9363173
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM MONITORING; BEAM MONITORS; BEAM POSITION; CAPACITORS; ELECTRODES; PARTICLE BOOSTERS; TOROIDAL CONFIGURATION; TRANSFORMERS; ZGS
Descriptors DEC
ACCELERATORS; ANNULAR SPACE; CONFIGURATION; CYCLIC ACCELERATORS; ELECTRICAL EQUIPMENT; MEASURING INSTRUMENTS; MONITORING; SYNCHROTRONS

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent