Published 1985 | Version v1
Miscellaneous

Canadian high burnup fuel experience

  • 1. Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.
  • 2. Ontario Hydro, Toronto, ON (Canada)

Description

All Canada's commercial irradiation experience is with the natural UO2, once-through, fuel cycle. However, AECL has also accumulated a substantial data base for MOX [(U,Pu)O2 and (Th,Pu)O2 and SEU [(≤ 2 wt% U-235(O2]. The data base incorporates normal operating conditions, including power ramps, to burnups in excess of 1000 MW.h/kgHE (40 000 MW.d/TeHE) at a range of linear powers. In the SEU data base is a well-documented program on the advanced annular fuel/graphite disc fuel designs for high power and burnup applications. There is also a significant instrumented irradiation support program based on SEU. The studies have not identified any previously unrecognized life-limiting phenomena which would preclude use of the current standard CANDU fuel design to burnups of at least 600 MW.h/kgHE (25 000 MW.d/TeHE)

Part of:
Proceedings of the Canadian Nuclear Society sixth annual conference

Additional details

Publishing Information

Imprint Title
Proceedings of the Canadian Nuclear Society sixth annual conference
Imprint Pagination
693 p.
Journal Page Range
p. 6.26-6.32.
Report number
INIS-mf--12870

Conference

Title
Canadian Nuclear Society 6. annual conference.
Dates
3-4 Jun 1985.
Place
Ottawa, ON (Canada).

Optional Information