Published 2015 | Version v1
Journal article

Several peaks of total current in Trichel pulse

  • 1. NSC ''Kharkov Institute of Physics and Technolog'' Kharkov (Ukraine)

Description

The numerical simulations of negative corona at constant voltage in Trichel pulse mode are carried out in assumptions of presence and absence of photoemission from cathode. In absence of photoemission two peaks of total current or the step before the main peak were obtained for very small values of ion-electron emission coefficient. In presence of photoemission there were observed several maximums, connected with instability development of the process based on radiation of photons, photoemission, and avalanche multiplication

Additional details

Publishing Information

Journal Title
Voprosy Atomnoj Nauki i Tekhniki
Journal Issue
no.1-100/95
Journal Page Range
p. 243-245
ISSN
1562-6016

INIS