Detection of heavy-water leaks in nuclear reactors : a novel method
Creators
- 1. Technical Physics and Prototype Engg. Division, Bhabha Atomic Research Centre, Mumbai (India)
Description
Technical Physics and Prototype Engineering Division, BARC has designed, developed and produced several high sensitivity mass spectrometer helium leak detectors over a period of two decades. Sometimes back, when there was a problem of detecting heavy water leaks in situ in one of the nuclear power reactors of the Department of Atomic Energy, it was referred to this division for a technical solution. After discussing with the site engineers, the various problems involved in the on-line detection of heavy water leaks especially near the end fittings of the coolant assemblies, a novel method of leak detection was developed. Some of the salient features of the method and the results obtained in the laboratory tests are given in this paper. (author)
Additional details
Publishing Information
- Journal Title
- Bulletin of the Indian Vacuum Society
- Journal Volume
- 5
- Journal Issue
- 2
- Journal Page Range
- p. 27-31
- CODEN
- BIVSES
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 33062239
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- HEAVY WATER; JOINTS; LEAK DETECTORS; LEAKS; MASS SPECTROMETERS; NUCLEAR POWER PLANTS; REACTOR COOLING SYSTEMS; SENSITIVITY; SIGNAL-TO-NOISE RATIO
- Descriptors DEC
- COOLING SYSTEMS; DEUTERIUM COMPOUNDS; ENERGY SYSTEMS; HYDROGEN COMPOUNDS; MEASURING INSTRUMENTS; NUCLEAR FACILITIES; OXYGEN COMPOUNDS; POWER PLANTS; REACTOR COMPONENTS; SPECTROMETERS; THERMAL POWER PLANTS; WATER
Optional Information
- Notes
- 3 figs.