Published January 1983 | Version v1
Report Open

Accurate method of the magnetic field measurement of quadrupole magnets

Description

We present an accurate method of the magnetic field measurement of the quadrupole magnet. The method of obtaining the information of the field gradient and the effective focussing length is given. A new scheme to obtain the information of the skew field components is also proposed. The relative accuracy of the measurement was 1 x 10-4 or less. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

15053106.pdf

Files (496.0 kB)

Name Size Download all
md5:dd429f06925de047bc2f7cd89b4f1bcd
496.0 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
21 p.
Report number
KEK--82-13

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
15053106
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
ACCURACY; FOCUSING; HARMONICS; MAGNET COILS; MAGNETIC FIELDS; MAGNETIC FLUX; MAGNETS; QUADRUPOLES; SPATIAL DISTRIBUTION
Descriptors DEC
DISTRIBUTION; ELECTRIC COILS; ELECTRICAL EQUIPMENT; EQUIPMENT; MULTIPOLES; OSCILLATIONS