Description

The report summarizes practical experience obtained by the application of the expert system PES-PEPA developed for WWER 440, type V230/V213 nuclear power plants. As an example, it shows its ability to identify, independently on the personnel activity, the presence of a damaged FE in the core, to optimize transients with the aim to limit radioactivity releases and to assess burnup of the damaged fuel assembly. (author). 4 refs, 7 figs

Part of:
Fuel failure in normal operation of water reactors: Experience, mechanisms and management

Additional details

Publishing Information

Imprint Title
Fuel failure in normal operation of water reactors: Experience, mechanisms and management
Imprint Pagination
288 p.
Journal Page Range
p. 100-105.
ISSN
1011-4289
Report number
IAEA-TECDOC--709

Conference

Title
Experience, mechanisms and management.
Acronym
Technical committeee meeting on fuel failure in normal operation of water reactors
Dates
26-29 May 1992.
Place
Dimitrovgrad (Russian Federation).

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
24067256
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BURNUP; EXPERT SYSTEMS; FAILED ELEMENT DETECTION; FISSION PRODUCT RELEASE; FISSION PRODUCTS; OPTIMIZATION; TRANSIENTS; WWER-3 REACTOR
Descriptors DEC
DETECTION; ENRICHED URANIUM REACTORS; ISOTOPES; MATERIALS; POWER REACTORS; PWR TYPE REACTORS; RADIOACTIVE MATERIALS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS