Published May 2010 | Version v1
Journal article

Decontamination of metal parts in fire alarm production line decommissioning

  • 1. China Academy of Engineering and Physics, Mianyang (China)

Description

Based on the contamination characteristics and the results of decontamination experiment, the decontamination program for metal parts in fire alarm production line was selected. The decontamination was carried out through priliminary decontamination, chemical and mechanical decontamination, respectively. Total decontamination area was 2 584.3 m2. The clearance efficiency was 86.6%, with good results. (authors)

Additional details

Publishing Information

Journal Title
Radiation Protection (Taiyuan)
Journal Volume
30
Journal Issue
3
Journal Page Range
p. 170-174, 194
ISSN
1000-8187

Optional Information

Notes
2 figs., 7 tabs., 5 refs.