Hydrogen isotope exchange and conditioning in graphite limiters used in the Tokamak Fusion Test Reactor
- 1. Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08544
Description
Isotopic exchange experiments performed in the Tokamak Fusion Test Reactor (TFTR) are used to examine the outgassing and diffusive properties of graphite used as the plasma limiter. Changeover from hydrogen to deuterium for different periods ranges from approx.600 to 60 plasma discharges, which appears to be correlated in the limiter temperature. We present a simple analytical model that predicts a fast transient (approx.10 plasma discharges) changeover, where the deuterium fueling dilutes the adsorbed and near surface hydrogen, and a slowly changing term where bulk hydrogen diffuses to the surface. Using this model we can extract an activation energy for diffusion of 0.15 +- 0.02 eV. We hypothesize that interpore diffusion for this porous (approx.15%) material is consistent with our observations
Additional details
Publishing Information
- Journal Title
- J. Vac. Sci. Technol., A
- Journal Volume
- 4
- Journal Issue
- 3
- Series
- J. Vac. Sci. Technol., A.
- Journal Page Range
- 1198-1202
- ISSN
- 0734-2101
- CODEN
- JVTAD
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17070852
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ADSORPTION; ATOM TRANSPORT; DEGASSING; DEUTERIUM; DIFFUSION; GRAPHITE; HYDROGEN; IMPURITIES; ISOTOPIC EXCHANGE; LIMITERS; SURFACE TREATMENTS; TFTR TOKAMAK
- Descriptors DEC
- CARBON; CLOSED PLASMA DEVICES; ELEMENTS; HYDROGEN ISOTOPES; ISOTOPES; LIGHT NUCLEI; NEUTRAL-PARTICLE TRANSPORT; NONMETALS; NUCLEI; ODD-ODD NUCLEI; RADIATION TRANSPORT; STABLE ISOTOPES; THERMONUCLEAR DEVICES; TOKAMAK DEVICES