Published June 1996 | Version v1
Report Open

HANARO core channel flow-rate measurement

  • 1. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

Description

HANARO core consists of 23 hexagonal flow tubes and 16 cylindrical flow tubes. To get the core flow distribution, we used 6 flow-rate measuring dummy fuel assemblies (instrumented dummy fuel assemblies). The differential pressures were measured and converted to flow-rates using the predetermined relationship between AP and flow-rate for each instrumented dummy fuel assemblies. The flow-rate for the cylindrical flow channels shows +-7% relative errors and that for the hexagonal flow channels shows +-3.5% relative errors. Generally the flow-rates of outer core channels show smaller values compared to those of inner core. The channels near to the core inlet pipe and outlet pipes also show somewhat lower flow-rates. For the lower flow channels, the thermal margin was checked by considering complete linear power histories. From the experimental results, the gap flow-rate was estimated to be 49.4 kg/s (cf. design flow of 50 kg/s). 15 tabs., 9 figs., 10 refs. (Author) .new

Availability note (English)

MF available from INIS under the Report Number.

Files

27063163.pdf

Files (1.3 MB)

Name Size Download all
md5:a72e32b3b4b1a5432d94b05c0a7a5170
1.3 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
47 p.
Report number