Pressure pulses hit the spot at Surry

  • 1. Westinghouse Electric Corp., Pittsburgh, PA (United States)
  • 2. Virginia Power Co., Glen Allen, VA (United States)

Description

A new approach to the removal of sludge and corrosion products from steam generator tube surfaces and crevices is described. It combines the mechanical pressure pulse cleaning process with chemical cleaning by solvents. The pressure pulses introduce nitrogen into the steam generator every 10 sec during the entire chemical cleaning fill, hold and drain cycles. The process, called Chemically Enhanced Pressure Pulse Cleaning improves cleaning and reduces the corrosive effects of solvents on steam generator components by a factor of two to four. It has been successfully applied at Virginia Power's Surry 1 and 2 PWR plants in the USA. Deposits totalling 38,000 lbs were removed and the success of the operation was confirmed by extensive video inspection. (UK)

Additional details

Publishing Information

Journal Title
Nuclear Engineering International
Journal Volume
40
Journal Issue
493
Journal Page Range
p. 26-27.
ISSN
0029-5507
CODEN
NEINBF

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
26071594
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
CLEANING; STEAM GENERATORS; SURRY-1 REACTOR; SURRY-2 REACTOR; TUBES
Descriptors DEC
BOILERS; ENRICHED URANIUM REACTORS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS