Dose evaluation for paediatric chest x-ray examinations in Brazil and Sudan: low doses and reliable examinations can be achieved in developing countries
Creators
- 1. FIOCRUZ-Escola Nacional de Saude Publica-CESTEH, Rua Leopoldo Bulhoes 1480, Manguinhos, 21041-210 Rio de Janeiro (Brazil)
- 2. Departamento de FIsica Medica, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, 22780-160 Rio de Janeiro (Brazil)
- 3. Instituto de Pediatria e Puericultura Martagao Gesteira, UFRJ, 21490-910 Rio de Janeiro (Brazil)
- 4. FIOCRUZ-Instituto Fernandes Figueira, Rio de Janeiro (Brazil)
- 5. Physics Department, Faculty of Sciences, Khartoum University, Khartoum (Sudan)
Description
Radiation protection in paediatric radiology deserves special attention since it is assumed that children are more sensitive to radiation than adults. The aim of this work is to estimate the entrance skin dose (ESD), the body organ dose (BOD) and the effective dose (E) for chest x-ray exposure of paediatric patients in five large units, three in Sudan and two in Brazil, and to compare the results obtained in both countries with each other and with other values obtained by some European countries. Two examination projections have been investigated, namely, postero-anterior (PA) and antero-posterior (AP). The age intervals considered were: 0-1 year, 1-5 years, 5-10 years and 10-15 years. The results have been obtained with the use of a software called DoseCal. Results of mean ESD for the age interval 1-5 years and AP projection are: 66 μGy (Instituto de Pediatria e Puericultura Martagao Gesteira-IPPMG Hospital), 41, 86 and 68 μGy (Instituto Fernandes Figueira-IFF Hospital), 161 μGy (Omdurman Hospital), 395 μGy (Khartoum Hospital) and 23 μGy (Ahmed Gasim Hospital). In the case of the IFF Hospital, the results refer, respectively, to rooms 1, 2 and for the six mobile equipments. The reference dose values given by the European Guidelines were exceeded in the Khartoum Hospital whilst in all the other hospitals results obtained were below CEC reference values and comparable with the results found in Sweden, Germany, Spain and Italy. The mean E for the same age interval was 11 μSv in the IPPMG, 6, 15 and 11 μSv in the IFF, respectively for rooms 1, 2 and the 6 mobiles, 25 μSv in the Omdurman Hospital, 45 μSv in the Khartoum Hospital and 3 μSv in the Ahmed Gasim Hospital. These are some examples of the large discrepancies that have been detected in this survey
Availability note (English)
Available online at http://stacks.iop.org/0031-9155/49/1017/pmb4_6_012.pdf or at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/Additional details
Identifiers
- URL
- http://stacks.iop.org/0031-9155/49/1017/pmb4_6_012.pdf; http://www.iop.org/;
- DOI
- 10.1088/0031-9155/49/6/012;
- PII
- S0031-9155(04)70887-8;
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 49
- Journal Issue
- 6
- Journal Page Range
- p. 1017-1031
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 35070709
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CHEST; CHILDREN; COMPUTER CODES; DEVELOPING COUNTRIES; DOSES; EVALUATION; HOSPITALS; MAXIMUM PERMISSIBLE EXPOSURE; PATIENTS; RADIATION PROTECTION; RADIOLOGY; RECOMMENDATIONS; SKIN
- Descriptors DEC
- AGE GROUPS; ANIMALS; BODY; BUILDINGS; MAMMALS; MAN; MEDICAL ESTABLISHMENTS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PRIMATES; SAFETY STANDARDS; STANDARDS; VERTEBRATES