Published December 2015 | Version v1
Journal article

Experience of non metallic silica based 68Ge/68Ga ITG generator: 68Ga labelled radiopharmaceuticals

  • 1. Department of Nuclear Medicine and Molecular Imaging, Tata Memorial Hospital, Mumbai (India)

Description

Continuous development of 68Ge/68Ga generator system open a new era in development of 68Ga labelled radiopharmaceuticals. Earlier generator system used metallic column made up of alumina, TiO2, SnO2 and pyrogallolformaldehyde organic resin as an adsorbent. ITG developed new generator system which uses non-metallic silica based column and 0.05M HCL as eluate. Non-metallic column yields Ga (III) in pure ionic form which further improves final yield of labelled product. Hence, we have evaluated labelling efficiency of 68Ga labelled radiopharmaceuticals using ITG 68Ge/68Ga generator system. We assessed the labelling performance of two ITG 68Ge/68Ga generator systems of 30mci each. ITG provided self-shielded iQS fluidic module for labelling purpose. First generator was replaced after six month of installation. We performed 33 labelling procedure for 68Ga-DOTANOC and 10 for PSMA using first generator. After inception of second generator since July 2015, we labelled 68Ga –PSMA (n = 30) and 68Ga-DOTANOC (n = 13). 25 μgm of peptide (DOTANOC Acetate) and 900μl of 0.25M sodium acetate was used for labelling with 68Ga. For 68Ga-PSMA labelling 5 μgm of peptide (DKFZ-PSMA- 11) and 1ml of 0.25M sodium acetate buffer was used. Elution was done with 0.05M HCL. After heating for 10 min at 100℃ labelled 68Ga-DOTANOC product was passed through C8 cartridge and 68Ga-PSMA through C18 cartridge. Labelled product was extracted with 50% ethanol as an eluent. Waste and product got collected in separate vials. pH of labelled product was measured. Radiochemical purity of 68Ga-DOTANOC was determined by ITLC method using 0.1M tri-sodium acetate as a solvent. Radiochemical stability was evaluated after 2-3 hrs. Results and We calculated labelling efficiency of 68Ga labelled product using both generators. Using first generator labelling efficiency of 68Ga-DOTANOC was 71% (n = 24, SDEV=0.065, pH=5.5).Low yield was reported nine times (40-55%). Low yield of 68Ga-PSMA was 45-60% (n = 3). Labelling efficiency of 68Ga-PSMA was 79 % (n = 7, SDEV=0.072, pH=5.5). Radiochemical purity was >93%. RCP was >90% after 3 hrs. (author)

Additional details

Publishing Information

Journal Title
Indian Journal of Nuclear Medicine
Journal Volume
30
Journal Issue
5,suppl
Journal Page Range
p. 25
ISSN
0972-3919

Conference

Title
47. annual conference of the society of nuclear medicine, India
Acronym
SNMICON-2015
Dates
3-6 Dec 2015
Place
Ahmedabad (India)