Published February 1986 | Version v1
Journal article

An energy resolution test on a SCG1-C scintillator glass at intermediate energies

  • 1. Istituto di Fisica Superiore dell'Universita di Torino

Description

The authors performed a test of a SCG1-C scintillator glass (Ohara Optical Glass Manufactoring Co., Ltd) at the CERN SC with electrons at energies from 100 to 300 Mev. The block surface was 15 x 15 cm2 and its length was 43.5 cm. corresponding to 10 radiation lengths. The energy resolution of the SCG1-C block was measured at five momentum values

Additional details

Publishing Information

Journal Title
IEEE Trans. Nucl. Sci.
Journal Volume
NS-33
Journal Issue
1
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
vp.
ISSN
0018-9499
CODEN
IETNA

Conference

Title
IEEE nuclear science symposium.
Dates
23-25 Oct 1985.
Place
San Francisco, CA (USA).

Optional Information

Secondary number(s)
CONF-851009--.