Dosimetric study of a brachytherapy treatment of esophagus with Brazilian 192Ir sources using an anthropomorphic phantom

  • 1. Instituto de Pesquisas Energéticas e Nucleares, Comissão Nacional de Energia Nuclear (IPEN-CNEN/SP), Av. Prof. Lineu Prestes, 2242, 05508-000 SP (Brazil)
  • 2. Departamento de Física, Universidade Federal de Sergipe, 49100-000 São Cristovão, SE (Brazil)
  • 3. Área de Ciências Tecnológicas, Centro Universitário Franciscano (UNIFRA), Rua dos Andradas, 1614, 97010-032 Santa Maria, RS (Brazil)

Description

Several radioisotopes are produced at Instituto de Pesquisas Energéticas e Nucleares for the use in medical treatments, including the activation of 192Ir sources. These sources are suitable for brachytherapy treatments, due to their low or high activity, depending on the concentration of 192Ir, easiness to manufacture, small size, stable daughter products and the possibility of re-utilization. They may be used for the treatment of prostate, cervix, head and neck, skin, breast, gallbladder, uterus, vagina, lung, rectum, and eye cancer treatment. In this work, the use of some 192Ir sources was studied for the treatment of esophagus cancer, especially the dose determination of important structures, such as those on the mediastinum. This was carried out utilizing a FASH anthropomorphic phantom and the MCNP5 Monte Carlo code to transport the radiation through matter. It was possible to observe that the doses at lungs, breast, esophagus, thyroid and heart were the highest, which was expected due to their proximity to the source. Therefore, the data are useful to assess the representative dose specific to brachytherapy treatments on the esophagus for radiation protection purposes. - Author-Highlights: • The use of brachytherapy sources was studied for the treatment of esophagus cancer. • FASH anthropomorphic phantom and MCNP5 Monte Carlo code were employed. • The doses at lungs, breast, esophagus, thyroid and heart were the highest. • The data is useful to assess the representative doses of treatments on the esophagus

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radphyschem.2013.11.029

Additional details

Identifiers

DOI
10.1016/j.radphyschem.2013.11.029;
PII
S0969-806X(13)00637-3;

Publishing Information

Journal Title
Radiation Physics and Chemistry (1993)
Journal Volume
104
Journal Page Range
p. 240-243
ISSN
0969-806X
CODEN
RPCHDM

Conference

Title
1. international conference on dosimetry and its applications
Dates
23-28 Jun 2013
Place
Prague (Czech Republic)

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.