This report presents the basis on which the BWR/6 fuel assemblies are evaluated to demonstrate their adequacy for sustaining combined peak loadings from the Safe Shutdown Earthquake and Loss-of-Coolant Accident events at rated operating temperatures. This report presents the methods for determining seismic accelerations, seismic loadings and blowdown loadings, as well as the detailed evaluations of the fuel assembly structural integrity

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
106 p.
Report number
NEDO--21175

Optional Information

Notes
General Electric Co., San Jose, CA.