Thickness Evaluation of Pipeline Using Density Profile on a Radiograph
- 1. Korea Inspection and Engineering R and D Center, Seoul (Korea, Republic of)
- 2. SungKyunKwan University, Suwon (Korea, Republic of)
Description
The computer simulation has been done for non-insulated and insulated pipes which are vacant or half filled with liquid. The simulation results showed that the density profile on the radiography is continuous and symmetrical around the center of pipe in the case of vacant pipe. On the other hand the density profiles are not symmetrical and depend on geometrical setting for radiography in the case of half filled pipes. Finally, experimental testing on a non-insulated carbon steel pipe with artificial notches of different depth is carried out using Ir-192 and industrial film. Comparing the measured density profile on the radiograph to the calculated one, it has been shown that it is possible to evaluate thickness variation by measuring density profile on a radiograph
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society for Nondestructive Testing
- Journal Volume
- 22
- Journal Issue
- 5
- Series
- 5 refs, 10 figs
- Journal Page Range
- p. 483-489
- ISSN
- 1225-7842
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 42054431
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- COMPUTER CALCULATIONS; COMPUTERIZED SIMULATION; DENSITY; EVALUATION; PIPELINES; THICKNESS
- Descriptors DEC
- DIMENSIONS; PHYSICAL PROPERTIES; SIMULATION