Nonbiodegradable Expanded Polytetrafluoroethylene-Covered Stent Implantation in Porcine Peripheral Arteries: Histologic Evaluation of Vascular Wall Response Compared with Uncoated Stents

  • 1. Cardiac Catheterization Laboratory, Istituto Policlinico S. Donato, Via Morandi 30, I-20097 S. Donato Milanese, Milan (Italy)
  • 2. Institute of Pathology, S. Matteo Hospital, University of Pavia, P.zzale Golgi 19, I-27100 Pavia (Italy)
  • 3. Institute of Vascular Surgery, S. Matteo Hospital, University of Pavia, P.zzale Golgi 19, I-27100, Pavia (Italy)
  • 4. Institute of Radiology, S. Matteo Hospital, University of Pavia, P.zzale Golgi 19, I-27100 Pavia (Italy)
  • 5. Department of Pathology, Armed Force Institute of Pathology, Bldg. 54, 6825 16th Street, Washington, DC 20036-6000 (United States)

Description

Purpose: To test the vascular wall response to an expanded polytetrafluoroethylene-covered stent, compared with conventional stenting, up to 6 months after deployment in the vascular district of a swine model.Methods: Fourteen minipigs underwent implantation of expanded polytetrafluoroethylene-covered stents (CS) and bare stents (BS) in five peripheral arteries. Animals were killed at different time points (from 1 to 180 days). Histopathologic assessment by morphologic and morphometric analysis and by scanning electron microscopy (SEM) were used to assess the incorporation characteristics and re-endothelialization extent of the two types of stents.Results: A total of 70 stents (14 CS and 14 BS in the renal arteries; 28 CS in the iliac arteries, and 14 CS in the aorta) were implanted. Microscopic examination confirmed the absence of occlusive thrombi in both the CS and BS groups. Microthrombi were observed in 10 of 13 CS (77% of cases) and in four of four BS (100% of cases, p < 0.05). Inflammation was mild in 69% of segments in which a CS was implanted and in 74% of segments in which a BS was implanted (p= NS), while a severe inflammatory reaction was observed in 6% of CS segments and in 8% of BS segments (p= NS). No differences were detected at the long-term analysis between neointimal thickness in CS compared with BS segments (0.46 ± 0.18 mm vs 0.42 ± 0.26 mm at 90 days and 0.36 ± 0.08 mm vs 0.35 ± 0.04 mm at 180 days; pNS, respectively). At SEM analysis, re-endothelization was evident 15 days after the implant in both CS and BS starting from the stent edges.Conclusion: CS implantation did not elicit a more severe thrombotic deposition compared with that of BS. A similar inflammatory reaction of the arterial wall was present in the two stent groups 3 and 6 months following the implant. In addition, CS implantation did not stimulate excessive neointimal formation when compared with BS

Additional details

Identifiers

Publishing Information

Journal Title
Cardiovascular and Interventional Radiology
Journal Volume
24
Journal Issue
4
Journal Page Range
p. 260-270
ISSN
0174-1551
CODEN
CAIRDG

Optional Information

Copyright
Copyright (c) 2001 Springer-Verlag New York Inc.