Published April 1981 | Version v1
Journal article

CEGB Magnox gas-cooled reactor operating performances 1962 to 1980

  • 1. Central Electricity Generating Board, Gwynedd (UK). Wylfa Power Station

Description

Details of fuel, costs of generation and number of employees for CEGB nuclear power stations from 1967 to 1980 are given. The electricity supplied, and average load percent of average maximum output capacity for Bradwell, Berkeley, Trawsfynydd, Hinkley Point, Dungeness, Sizewell, Oldbury and Wylfa are given for each station. The parameters and statistics for these stations as well as Calder Hall, Chapelcross, Latina, Hunterston A and Tokai-Mura are also presented. (U.K.)

Additional details

Publishing Information

Journal Title
Nucl. Energy
Journal Volume
20
Journal Issue
2
Series
Nucl. Energy.
Journal Page Range
127-132
ISSN
0140-4067

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
13645686
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
COMPILED DATA; ECONOMY; MAGNOX TYPE REACTORS; NUCLEAR POWER PLANTS; PERFORMANCE; REACTOR OPERATION; UNITED KINGDOM
Descriptors DEC
DATA; EUROPE; INFORMATION; NATURAL URANIUM REACTORS; NUCLEAR FACILITIES; NUMERICAL DATA; OPERATION; POWER PLANTS; POWER REACTORS; REACTORS; THERMAL POWER PLANTS