Published June 2006 | Version v1
Journal article

Refrigerant mass charge distribution in a domestic refrigerator. Part II: steady state conditions

  • 1. Department of Energy Technology, Royal Institute of Technology, SE 100 44 Stockholm (Sweden)

Description

Experimental results are presented of the refrigerant mass charge distribution in a steady state operating domestic refrigerator at varied thermal loads. It was found that the charge decreased in the evaporator and increased in the condenser and compressor upon increased thermal load. No subcooling or superheat was observed over the range of capacities tested (74-145 W). The combination of a low side accumulator and an expansion device with high capacity (short capillary tube) explained this. The study suggests that a capillary tube throttled cooling system, with a floating condensation temperature, can handle large load variations without becoming destabilised (superheat or subcooling) just like a more sophisticated thermostatic expansion device control system

Additional details

Identifiers

DOI
10.1016/j.applthermaleng.2005.10.004;
PII
S1359-4311(05)00332-7;

Publishing Information

Journal Title
Applied Thermal Engineering
Journal Volume
26
Journal Issue
8-9
Journal Page Range
p. 866-871
ISSN
1359-4311
CODEN
ATENFT

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
37063678
Subject category
S42: ENGINEERING;
Descriptors DEI
CHARGE DISTRIBUTION; COMPRESSORS; CONTROL SYSTEMS; COOLING SYSTEMS; EQUIPMENT; EXPANSION; REFRIGERANTS; REFRIGERATORS; STEADY-STATE CONDITIONS; SUBCOOLING; TANKS; TUBES
Descriptors DEC
CONTAINERS; COOLING; ENERGY SYSTEMS; FLUIDS; WORKING FLUIDS