Published December 2001 | Version v1
Journal article

Digitizing pediatric chest radiographs: comparison of low-cost, commercial off-the-shelf technologies

  • 1. Dept. of Radiology, Honolulu, HI (United States)
  • 2. Dept. of Clinical Investigation, Tripler Army Medical Center, Honolulu, HI (United States)
  • 3. Dept. of Pediatrics, Tripler Army Medical Center, Honolulu, HI (United States)
  • 4. AKAMAI Project Office, Tripler Army Medical Center, 1 Jarrett White Road, Honolulu, HI 96859-5000 (United States)

Description

Objective: To compare low-cost, off-the-shelf technology for digitizing pediatric chest radiographs. Materials and methods: Forty pediatric chest radiographs (hard copy), each with a single abnormality, were digitized using a commercial film digitizer and two low-cost methods: a digital camera and a flatbed scanner. A stratified, randomized, block design was used where 20 readers evaluated 40 different images to determine the ability to accurately detect the abnormality. Readers then rated all 160 images (40 images x 4 methods) for conspicuity of the abnormality and overall image quality. Results: Abnormalities were correctly identified on 82.3 % of hard copy images, 82.9 % of flatbed scanner images, 74.3 % of film digitizer images, and 69.7 % of digital camera images (p < 0.05) when compared to hard copy or flatbed scanner images. Lesion conspicuity was rated higher on hard copy (p < 0.05) than all digitized images. Conspicuity ratings were similar for flatbed scanner and film digitizer images, but lower in digital camera images (p < 0.05). For overall image quality, all were rated significantly different from each other (p < 0.05), with hard copy > flatbed scanner > film digitizer > digital camera images. Conclusion: A low-cost flatbed scanner yielded digital pediatric chest images which were significantly superior to digital camera images While flatbed scanner images were interpreted with the equivalent diagnostic accuracy of hard copy images, they were rated lower for image quality and lesion conspicuity. (orig.)

Additional details

Publishing Information

Journal Title
Pediatric Radiology
Journal Volume
31
Journal Issue
12
Journal Page Range
p. 841-847
ISSN
0301-0449
CODEN
PDRYA5

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
33027947
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; CHEST; COST BENEFIT ANALYSIS; DIGITAL SYSTEMS; IMAGES; PEDIATRICS
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; ECONOMIC ANALYSIS; ECONOMICS; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY

Optional Information

Notes
With 3 figs., 3 tabs.