Published October 1995 | Version v1
Miscellaneous

Safety analysis of VVER-440/230 primary piping in respect to leak-before-break

  • 1. Siemens AG, Erlangen (Germany)
  • 2. Electricite de France (France)
  • 3. Framatome (France)

Description

Within the European programme TACIS (Technical Assistance for the Community of Independent States) a programme called 'Primary Circuit Integrity: Application of Leak Before Break Concept' is in progress. The objective of the TACIS project is to investigate whether the leak before break concept may be applied to the primary circuit of the following WWER-440/230 type units: Novovoronezh 3 and 4; Kola 1 and 2. The structure of the programme and the data required are discussed. (Z.S.) 3 refs

Part of:
Proceedings of the international topical meeting on VVER safety

Additional details

Publishing Information

Imprint Title
Proceedings of the international topical meeting on VVER safety
Imprint Pagination
416 p.
Journal Page Range
p. 241-246.
Report number
INIS-mf--14715

Conference

Title
International topical meeting on VVER safety.
Dates
21-23 Sep 1995.
Place
Prague (Czech Republic).