Published 1982
| Version v1
Report
Open
Study of the accuracy of particle track detection by proportional chambers using cathode information readout
- 1. Joint Inst. for Nuclear Research, Dubna (USSR). Dept. of New Acceleration Methods
- 2. Moskovskij Inzhenerno-Fizicheskij Inst. (USSR)
Description
Results are presented of a study of the accuracy in detecting relativistic particle coordinates in proportional chambers using the cathode information read out. The width of cathode strips was 2 mm and the anode to cathode distance-4 mm. For the tracks perpendicular to the chamber plane the detection accuracy was 50 μm. Two methods of calculation of the centre of the induced charge distribution on the cathode strips are described: by the centre of gravity and by least square fit. Studies are presented of the accuracy in measuring the track coordinates as a function of the charge produced in avalanches. It is shown that for single-particle events the change of the width of the induced charge distribution does not exceed 1.2%
Availability note (English)
MF available from INIS under the Report Number.Files
14772844.pdf
Files
(224.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:3aab8516beb27418326babaff1e12217
|
224.7 kB | Preview Download |
System files
(25.2 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Исследование точности регистрации треков частиц пропорциональными камерами с катодным считыванием информации
Publishing Information
- Imprint Pagination
- 6 p.
- Report number
- JINR-R--9-82-724
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 14772844
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CATHODES; COORDINATES; EFFICIENCY; ELECTRIC CHARGES; ERRORS; LEAST SQUARE FIT; MULTIWIRE PROPORTIONAL CHAMBER; PARTICLE TRACKS; READOUT SYSTEMS; SPATIAL RESOLUTION; STABILITY
- Descriptors DEC
- ELECTRODES; MAXIMUM-LIKELIHOOD FIT; MEASURING INSTRUMENTS; NUMERICAL SOLUTION; PROPORTIONAL COUNTERS; RADIATION DETECTORS; RESOLUTION
Optional Information
- Notes
- 5 refs.; 7 figs.; 1 tab.; submitted to the journal NIM.