Published June 1987 | Version v1
Report Restricted

Failure analysis of ETAC [Enrichment Technology Applications Center] pressure vessel

Description

This report presents the results of an investigation into the failure of a graphite-epoxy composite cylinder. It investigates the quality of the as-fabricated cylinder and provides a verification of compressive material property input used in its design. The design is reevaluated in terms of the adjusted composition and material property input for its suitability for 18,000-psi pressure applications. A comparison between the composition and layup of a cylinder manufactured by Hitco is also provided, as well as the results of a pressurization test of an identical ETAC cylinder tested by the Naval Ocean Systems Center

Availability note (English)

Available from NTIS, PC A05/MF A01; 1 as DE87012451.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
79 p.
Report number
K/ETAC--22

INIS

Optional Information

Notes
Portions of this document are illegible in microfiche products.