Measurement of tune spread in the Tevatron versus octupole strength
Description
A experiment was performed in the Tevatron to measure the tune spread versus octupole strength. The experiment is sensitive to the relationship between octupole strength and current in the T:OZF circuit and to the octupole (and other non-linear focusing fields) in the Tevatron. The major motivation for the experiment was to determine the value of octupole excitation that minimizes the tune spread: this value is an estimate of the value required to obtain ''zero'' total octupole excitation in the extraction process. The experiment was performed using the strip-line kickers at A17 and the resonant Schottky pickups. The horizontal proton kicker was excited with a sine-wave from a vector signal analyzer (HP-89440A) and the horizontal proton signal was received. The gating circuitry normally used to select proton or antiproton bunches was by-passed. The response function was measured and recorded on a floppy disk. Measurements were initially made with a 200 Hz span (0.250 Hz frequency bins) and later with a 100 Hz span (0.125 Hz frequency bins). The data was all obtained at flattop (800 GeV) with Q39S and Q39C set to correct the 1/2 integer stop band and QXR (the extraction regulation system) turned off. No attempt was made to examine sensitivity to closed orbit, chromaticity, or any other machine parameters other than the zero harmonic octupoles. The tune varied slightly (presumably because of feed-down effects from the octupoles), but was approximately constant at 19.472 (only the fractional part was measured). The beam emittance was not measured because the flying wires were not working when these data were taken. The analysis of the data was accomplished by replotting the data from the floppy disk. The peak amplitude and the full width at 25% of the peak height were measured. Figures 1-7 show some of the data that was obtained. The vertical scales in figures 1-7 are adjusted so that the data span 80% of the full height of the screen. The hardware requires the markers to be measured points, so the width measured is not exactly at 25% of full height
Availability note (English)
Available from PURL: https://www.osti.gov/servlets/purl/15017295-pSCrSE/native/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 8 p.
- Report number
- FERMILAB-EXP--199
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 36104870
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- AMPLITUDES; ANTIPROTONS; BEAM EMITTANCE; EXCITATION; FERMILAB TEVATRON; FOCUSING; HARMONICS; OCTUPOLES; PROTONS; REGULATIONS; RESPONSE FUNCTIONS; SENSITIVITY; VECTORS
- Descriptors DEC
- ACCELERATORS; ANTIBARYONS; ANTIMATTER; ANTINUCLEI; ANTINUCLEONS; ANTIPARTICLES; BARYONS; CYCLIC ACCELERATORS; ELEMENTARY PARTICLES; ENERGY-LEVEL TRANSITIONS; FERMIONS; FUNCTIONS; HADRONS; LAWS; MATTER; MULTIPOLES; NUCLEI; NUCLEONS; OSCILLATIONS; PROTONS; SYNCHROTRONS; TENSORS
Optional Information
- Contract/Grant/Project number
- AC--02-76CH03000
- Funding organization
- US Department of Energy (United States)