Analysis of the formation of images fitness test and tolerance limits the x-ray diagnostics

  • 1. Pusat Rekayasa Perangkat Nuklir - BATAN, Kawasan Puspiptek Serpong, Tangerang Selatan 15314 (Indonesia)

Description

Image-forming analysis has been performed and conformance test tolerance limit plane x-ray Diagnostics. In forming an image on a plane x-ray is the ability of the penetrating power of x-rays on the matter. The purpose is to know how the occurrence of an image on a film formed by x-rays. So it can be understood the difference form the image on the parts of the body irradiated. Factors affecting the image radiography, among others, the magnitude mA, with a film focus distance (FFD), and the voltage (kV). Apart form the image in the process radiograph should also know the condition of the plane x-ray. in order to ensure the safety of the patient, operator and environment. It required function tests or test compliance (Compliance Testing). So the plane x-ray radiation safety requirements and provide information as precise and accurate diagnosis. Having done the analysis and research generated conformance test is still below the prevailing standard that is equal to 10 %. For an ideal image formation distance between the image and the focus tube is (90 cm - 100 cm) and the image area is a good width W1. (author)

Files

54046972.pdf

Files (892.3 kB)

Name Size Download all
md5:af65ec484bc08e76c765b85c5360f18d
892.3 kB Preview Download
Part of:
Proceedings of the National Seminar on Research and Management of Nuclear Devices, Book I

Additional details

Additional titles

Original title (Indonesian)
Analisis pembentukan gambar dan batas toleransi uji kesesuaian pada pesawat sinar-x diagnostik

Publishing Information

Publisher
Center for Accelerator Technology and Material Process, National Nuclear Energy Agency
Imprint Place
Yogyakarta (Indonesia)
Imprint Title
Proceedings of the National Seminar on Research and Management of Nuclear Devices, Book I
Imprint Pagination
362 p.
Journal Page Range
p. 157-163
ISSN
1410-8178
Report number
INIS-ID--107

Conference

Title
National Seminar on Research and Management of Nuclear Devices, Book I
Original Conference Title
Seminar Nasional Penelitian dan Pengelolaan Perangkat Nuklir, Buku I
Dates
27 Jul 2011
Place
Yogyakarta (Indonesia)

Optional Information

Notes
10 refs.; 3 tabs.; 6 figs. Imprint:Prosiding Seminar Nasional Penelitian dan Pengelolaan Perangkat Nuklir, Buku I