Published December 2021 | Version v1
Journal article

Smartphone-assisted ratiometric fluorescence sensing platform and logical device based on polydopamine nanoparticles and carbonized polymer dots for visual and point-of-care testing of glutathione

  • 1. School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016 (China)

Description

Highlights: • A dual-signals output sensing platform for rapid, sensitive and point-of-care testing of GSH was constructed. • The portable smartphone-assisted ratiometric chromaticity method was exploited to achieve the on-site detection of GSH. • An ingenious logical device reflecting GSH level was designed to provide a basis for the intelligent online analysis of GSH. • The sensing strategy was applied to monitor GSH in human serum samples with satisfactory results. As a crucial biothiol, glutathione (GSH) plays a key role in the organisms. Monitoring GSH level is of great significance for disease diagnosis and biomedical research. In this work, polydopamine (PDA) nanoparticles-red fluorescent carbonized polymer dots (r-CPDs) based ratiometric fluorescence sensing platform was constructed and employed for GSH assay. Dopamine (DA) could be oxidized by cobalt oxyhydroxide (CoOOH) nanosheets and further polymerized into PDA nanoparticles with green fluorescence. However, in the presence of GSH, CoOOH nanosheets were reduced and decomposed, which prevented the production of PDA nanoparticles. In the sensing system, green-emitting PDA nanoparticles were employed as a response unit and r-CPDs were used as an internal reference unit. With the addition of GSH, the green fluorescence of PDA nanoparticles decreased as well as the red fluorescence of system remained relatively stable. Importantly, a distinct fluorescence color evolution from green to red was presented with a serious of GSH concentrations. Based on this, a portable smartphone-assisted ratiometric chromaticity analytical method was developed to achieve the on-site visual detection of GSH. Both the established ratiometric fluorescence and ratiometric chromaticity sensing methods for GSH assay have the merits of wide linear range, high sensitivity and excellent accuracy, which are suitable for the determination of GSH in human serum and exhibit great application potential in rapid and accurate monitoring of the GSH levels in clinical. Moreover, an ingenious logical device reflecting GSH levels was designed based on the two different fluorescence signals, which provided a new strategy for the intelligent online detection of GSH in complex biological matrices.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2021.339165

Additional details

Identifiers

DOI
10.1016/j.aca.2021.339165;
PII
S0003267021009910;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
1188
Journal Page Range
vp.
ISSN
0003-2670
CODEN
ACACAM

Optional Information

Copyright
Copyright (c) 2021 Elsevier B.V. All rights reserved.