Published January 2000 | Version v1
Journal article

Heat removal characteristics of vault storage system with cross flow for spent fuel

  • 1. Central Research Inst. of Electric Power Industry, Abiko, Chiba (Japan). Abiko Research Lab.

Description

Since the amount of spent fuel to be stored is expected to steadily increase in Japan, a use of large-scale dry storage facilities is considered to be a promising method in practice at reasonable economic cost. The present study is concerned with the heat removal experiment of vault storage system adopting cross flow with passive cooling, using a 1/5 scale model. The results show that the flow pattern of air in the storage module strongly depends on the ratio of the buoyancy to the inertia force. A simple method to estimate air flow patterns in the storage module was proposed, where the Ri (Richardson) number was considered as the most representative parameter. Then the heat transfer rate from a storage tube to cooling air was estimated, which could apply to the design of a full-scale vault storage system with cross flow, in which dozens of storage tubes were placed. The acquired information was also used to optimize heat removal design of the vault storage system in the present study. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
195
Journal Issue
1
Journal Page Range
p. 57-68
ISSN
0029-5493
CODEN
NEDEAU

INIS

Country of Publication
Netherlands
Country of Input or Organization
Switzerland
INIS RN
31008636
Subject category
S20: FOSSIL-FUELED POWER PLANTS;
Descriptors DEI
COOLING; COST; ECONOMICS; FLUID FLOW; RADIOACTIVE WASTE STORAGE; SIMULATION; TEMPERATURE DISTRIBUTION; VELOCITY
Descriptors DEC
MANAGEMENT; STORAGE; WASTE MANAGEMENT; WASTE STORAGE

Optional Information

Notes
7 refs.