Published April 1987
| Version v1
Report
Restricted
High-Temperature Reactor Module Power Plant: Safety Analysis Report. Cooling Water Systems. Chapter 3.7
Creators
Description
Chapter 3.7 of the High-Temperature Reactor Module Power Plant: Safety Analysis Report. The general flow diagrams (Figures 3.7.1/1 and 2) show the interrelationship between the following Systems: - the circulating water System and wet/dry cooling tower - the conventional Service water system - the nuclear Service water System - the secured Service water system - the Service water system for the start-up and shutdown circuits - the conventional closed cooling water system - the operational component cooling system - the secured cooling system - the closed cooling wat.er system for the start-up and shutdown circuits
Files
Additional details
Publishing Information
- Imprint Pagination
- 21 p.
- Report number
- INIS-DE--22M0287
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 53059683
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- AUXILIARY WATER SYSTEMS; COOLING SYSTEMS; COOLING TOWERS; FEDERAL REPUBLIC OF GERMANY; FORSCHUNGSZENTRUM JUELICH; HTGR TYPE REACTORS; POWER PLANTS; SAFETY ANALYSIS; SHUTDOWN; TEMPERATURE RANGE 0400-1000 K; WATER
- Descriptors DEC
- AUXILIARY SYSTEMS; DEVELOPED COUNTRIES; ENERGY SYSTEMS; EUROPE; GAS COOLED REACTORS; GERMAN FR ORGANIZATIONS; GRAPHITE MODERATED REACTORS; HYDROGEN COMPOUNDS; NATIONAL ORGANIZATIONS; OXYGEN COMPOUNDS; REACTORS; TEMPERATURE RANGE; WESTERN EUROPE
Optional Information
- Notes
- Document from Juelich Preservation Project; Also available in German; Figs.