Published 2004 | Version v1
Journal article

Evaluation of Kjeldahl digestion method

  • 1. Zarai Taraqiati Bank Limited, Khanewal (Pakistan)
  • 2. Glasgow Univ., Glasgow (United Kingdom). Agricultural Chemistry Department

Description

The evaluation of the Kjeldahl digestion method was investigated by comparing measured values of total nitrogen, phosphorus and potassium using three salt and catalyst mixture in Standard Kjeldahl digestion method and Salicyclic acid Modification method with certified values of plant material as well as comparison was made for determination of total nitrogen from steam distillation method verses the Technicon Auto-analyzer, and phosphorus Ascorbic acid/Molybdate method verses Molybdate/ Metavanadate method on the Technicon Auto-Analyzer. The 1 g salt/catalyst mixture recovered less nitrogen than the 2.5 g in the standard Kjeldahl method due to the lower temperature and incomplete digestion in both plant and soil samples. The 2.5 g catalyst mixture partially recovered nitrate in the standard Kjeldahl method and the salicylic acid modification fail to recover all over nitrate in plant material. Use of 2.5 g salt catalyst mixture and selenium appears to promote nitrogen losses in salicylic acid modification method but not in the standard Kjeldahl method of digestion for soil samples. No interference of selenium or copper was observed in Nitrogen and Phosphorus on calorimetric determination. The standard Kjeldahl method with 2.5 g of salt/catalyst mixture of sodium sulphate copper sulphate (10:1) in 5 ml sulfuric acid were found suitable for determination of total Nitrogen, phosphorus and potassium. The steam distillation and the Technicon Auto-Analyzer technique measure similar amounts of ammonium nitrogen. However, the Technicon Auto analyzer technique is easier, rapid, higher degree of reproducibility, precise, accurate, reliable and free from human error. The amount of phosphorus measured by the Ascorbic acid/Molybdate method was more accurate than by the Molybdate/Metavanadate method on Technicon Auto-Analyzer. (author)

Additional details

Publishing Information

Journal Title
Journal of Research (Science)
Journal Volume
15
Journal Issue
2
Journal Page Range
p. 159-179
ISSN
1021-1012

INIS

Country of Publication
Pakistan
Country of Input or Organization
Pakistan
INIS RN
36030156
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
ANAEROBIC DIGESTION; KJELDAHL METHOD; NITROGEN; PHOSPHORUS; POTASSIUM; STEAM GENERATORS
Descriptors DEC
ALKALI METALS; BIOCONVERSION; BOILERS; DIGESTION; ELEMENTS; METALS; NONMETALS; VAPOR GENERATORS