Quantitative evaluation of MR perfusion imaging using blood pool contrast agent in subjects without pulmonary diseases and in patients with pulmonary embolism
Creators
- 1. University Hospital Jena, Institute of Diagnostic and Interventional Radiology II, Gera (Germany)
- 2. University Hospital Jena, Institute of Diagnostic and Interventional Radiology II, Jena (Germany)
- 3. Fraunhofer MEVIS - Institute for Medical Image Computing, Bremen (Germany)
- 4. SRH Klinikum Gera, Institute of Diagnostic and Interventional Radiology, Gera (Germany)
- 5. Suedharzkrankenhaus Nordhausen, Institute of Diagnostic and Interventional Radiology, Nordhausen (Germany)
- 6. University Hospital Jena, Department of Internal Medicine III, Jena (Germany)
Description
To assess the feasibility of time-resolved parallel three-dimensional magnetic resonance imaging (MRI) for quantitative analysis of pulmonary perfusion using a blood pool contrast agent. Quantitative perfusion analysis was performed using novel software to assess pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT) in a quantitative manner. The evaluation of lung perfusion in the normal subjects showed an increase of PBF, PBV ventrally to dorsally (gravitational direction), and the highest values at the upper lobe, with a decrease to the middle and lower lobe (isogravitational direction). MTT showed no relevant changes in either the gravitational or isogravitational directions. In comparison with normally perfused lung areas (in diseased patients), the pulmonary embolism (PE) regions showed a significantly lower mean PBF (20 ± 0.6 ml/100 ml/min, normal region 94 ± 1 ml/100 ml/min; P < 0.001), mean PBV (2 ± 0.1 ml/100 ml, normal region 9.8 ± 0.1 ml/100 ml; P < 0.001) and mean MTT (3.8 ± 0.1 s; normal region 6.3 ± 0.1; P < 0.001). Our results demonstrate the feasibility of using time-resolved dynamic contrast-enhanced MRI to determine normal range and regional variation of pulmonary perfusion and perfusion deficits in patients with PE. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-012-2428-zAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 22
- Journal Issue
- 8
- Journal Page Range
- p. 1748-1756
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 44008028
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARTERIES; BIOMEDICAL RADIOGRAPHY; BLOOD CIRCULATION; BLOOD FLOW; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; EMBOLI; GRAVITATION; LUNGS; NMR IMAGING; ORIENTATION; PERFUSED ORGANS; POSITIONING; RESPIRATORY SYSTEM DISEASES; TIME RESOLUTION
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESOLUTION; RESPIRATORY SYSTEM; TIMING PROPERTIES; TOMOGRAPHY