Evaluation of automated attenuation-based tube potential selection in combination with organ-specific dose reduction for contrast-enhanced chest CT examinations
Description
Aim: To evaluate the influence of attenuation-based tube potential selection (ATPS) in combination with organ-specific dose reduction (OSDR) on radiation dose and image quality of contrast-enhanced chest computed tomography (CT) examinations. Material and methods: Seventy consecutive patients (59.2 ± 16.1 years; 49 men; 21 women) were randomized into two groups and underwent contrast-enhanced chest CT using a 128 section CT scanner. CT examinations were performed as standard protocol in group A (n = 35) and with the activated novel dose-saving devices, OSDR and ATPS, in group B (n = 35). Objective [signal-to-noise (SNR) and contrast-to-noise ratio (CNR)] and subjective image quality (five-point scale; 1 = non diagnostic; 5 = excellent) as well as radiation dose (CTDIvol) were analysed. Results: CTDIvol of the protocol using OSDR and ATPS was significantly lower than in standard chest CT examinations (3.4 ± 1 versus 6.1 ± 2.3 mGy; p < 0.001). Although the level of noise was slightly elevated in group B (14.1 ± 1.7 versus 11.4 ± 1.9 HU; p < 0.01), no significant differences in SNR (17.1 ± 5 versus 16.3 ± 4.7) or subjective image quality (mean score of 4.6 versus 4.4) were observed between both imaging protocols. Conclusion: Attenuation-based tube potential selection in combination with organ-specific dose reduction essentially reduces the dose of chest CT in patients with normal body mass index (BMI) in clinical routine while maintaining subjective and objective image quality. - Highlights: • ATPS in combination with OSDR essentially reduces radiation exposure in chest CT. • ATPS combined with OSDR does not compromise image quality of chest CT examinations. • ATPS and OSDR can be recommended for clinical routine
Availability note (English)
Available from http://dx.doi.org/10.1016/j.crad.2014.02.008Additional details
Identifiers
- DOI
- 10.1016/j.crad.2014.02.008;
- PII
- S0009-9260(14)00081-6;
Publishing Information
- Journal Title
- Clinical Radiology
- Journal Volume
- 69
- Journal Issue
- 7
- Journal Page Range
- p. 721-726
- ISSN
- 0009-9260
- CODEN
- CLRAAG
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46120158
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CHEST; COMPUTERIZED TOMOGRAPHY; NOISE; PATIENTS; RADIATION DOSES
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DOSES; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.