Published March 15, 2019 | Version v1
Journal article

Multiple Bifurcated Covered Self-Expanding Metallic Stents for Complex Tracheobronchial Fistulas or Stenosis

  • 1. The First Affiliated Hospital of Zhengzhou University, Department of Interventional Radiology (China)
  • 2. The First Affiliated Hospital of Zhengzhou University, Department of Thoracic Surgery (China)

Description

Objective

We aimed to determine the safety and feasibility of bifurcated covered self-expanding stents for the treatment of complex tracheobronchial fistulas or stenosis.

Methods

Twenty-eight patients were treated by multiple bifurcated covered airway stents (Micro-Tech Co. Ltd., Nanjing, China), including 18 cases of gastrobronchial or gastrotracheal fistula, 6 cases of bronchopleural fistula and 4 cases of severe tracheobronchial stenosis. The large bifurcated covered stent was placed at the main carina, and the small stents were inserted into primary right carina or secondary left carina. Clinical and imaging data were retrospectively analyzed.

Results

Stents were successfully inserted in 27 patients at the first attempt. In total, 29 large bifurcated covered stents, 27 small bifurcated covered stents and 5 small bifurcated covered single-plugged stents were inserted. All patients with fistula could resume eating without coughing after the procedure. No perioperative death or severe complications occurred. Two patients underwent stent removal due to intolerance of stenting; the clinical success rate was 93% (26/28). Nineteen complications were found in 12 patients; 8 patients needed stent removal or replacement, for a major complication rate of 29% (8/28). Eight patients underwent successful stent removal due to complications. Fifteen patients died of tumors and one patient died of pulmonary infection. The median survival was 33 months. Fistula recurrence was found in one patient 5 months after stenting, and second small bifurcated covered stent was inserted.

Conclusions

Multiple bifurcated covered metallic stenting is effective and safe for complex tracheobronchial fistulas or stenosis, with good symptom palliation.

Additional details

Identifiers

Publishing Information

Journal Title
Cardiovascular and Interventional Radiology
Journal Volume
42
Journal Issue
3
Journal Page Range
p. 426-432
ISSN
0174-1551
CODEN
CAIRDG

Optional Information

Copyright
Copyright (c) 2019 Springer Science+Business Media, LLC, part of Springer Nature and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE)