Published July 1992 | Version v1
Report

Procedure for the arrangement of the reliability centered maintenance (RCM) activity at the Paks Nuclear Power Plant

  • 1. Paksi Atomeroemue Vallalat, Paks (Hungary)

Description

The use of the RCM approach for optimizing maintenance of technological systems is proposed. Details for the supervision of the system, as well as the evaluation of the system elements are described. The evaluation of the state of the system as a whole was performed to determine influence of individual elements. For each of the individual elements, positive or negative influence to the system capability is detected. (author). 1 fig

Part of:
Safety related maintenance in the framework of the reliability centered maintenance concept

Additional details

Publishing Information

Imprint Title
Safety related maintenance in the framework of the reliability centered maintenance concept
Imprint Pagination
204 p.
Journal Page Range
p. 69-79.
ISSN
1011-4289
Report number
IAEA-TECDOC--658

Conference

Title
Technical committee meeting on safety related maintenance in the framework of the reliability centered maintenance concept.
Dates
27-30 May 1991.
Place
Vienna (Austria).

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
23067889
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CONDENSER COOLING SYSTEMS; EVALUATION; INSPECTION; MAINTENANCE; NUCLEAR POWER PLANTS; PAKS-1 REACTOR; RELIABILITY
Descriptors DEC
AUXILIARY SYSTEMS; AUXILIARY WATER SYSTEMS; COOLING SYSTEMS; ENRICHED URANIUM REACTORS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS

Optional Information