Published December 2018 | Version v1
Journal article

Chemical decontamination of primary loop elbow and verification test in nuclear power plant

  • 1. Suzhou Nuclear Power Research Institute, Suzhou (China)

Description

The in-service chemical decontamination of reactor systems, equipment and components is essential for reducing individual and collective dose levels, which can compensate for the shortcomings of conventional radiation protection measures. The optimized chemical decontamination process was quickly selected by Cr-substituted magnetite oxide dissolution test and pre-oxidized film corrosion test. The decontamination factor is 3.08 in the practical application of the test in decontamination of a nuclear power plant primary loop elbow, while the corrosion depth of Z2CN18-10 base metal is much less than 1 μm. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Nuclear and Radiochemistry
Journal Volume
40
Journal Issue
6
Journal Page Range
p. 388-392
ISSN
0253-9950

Optional Information

Notes
6 figs., 1 tab., 9 refs.; http://dx.doi.org/10.7538/hhx.2018.YX.2017082