Published 2006
| Version v1
Miscellaneous
Open
Top flooding modeling with MAAP4 code
Description
An engineering top flooding model was developed in MAAP4.04d.4, the severe accident code used in EDF, to simulate the thermal-hydraulic phenomena that should take place if emergency core cooling (ECC) water was injected in hot leg during quenching. In the framework of the ISTC (International Science and Technology Centre), a top flooding test was proposed in the PARAMETER facility (Podolsk, Russia). The MAAP calculation of the PARAMETER top flooding test is presented in this paper. A comparison between top and bottom flooding was made on the bundle test geometry. According to this study, top flooding appears to cool quickly and effectively the upper plenum internals. (author)
Files
38115438.pdf
Files
(694.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:bf100a948cc0eb99a95c41c85f852a1b
|
694.9 kB | Preview Download |
Additional details
Publishing Information
- Publisher
- Nuclear Society of Slovenia
- Imprint Place
- Ljubljana (Slovenia)
- ISBN
- 961-6207-26-3
- Imprint Title
- Proceedings of the International Conference Nuclear Energy for New Europe 2006
- Imprint Pagination
- vp.
- Journal Page Range
- [9 p.]
- Report number
- INIS-SI--07-002
Conference
- Title
- International Conference Nuclear Energy for New Europe 2006
- Dates
- 18-21 Sep 2006
- Place
- Portoroz (Slovenia)
INIS
- Country of Publication
- Slovenia
- Country of Input or Organization
- Slovenia
- INIS RN
- 38115438
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ECCS; M CODES; QUENCHING; REACTOR ACCIDENT SIMULATION; TEST FACILITIES; THERMAL HYDRAULICS
- Descriptors DEC
- COMPUTER CODES; ENGINEERED SAFETY SYSTEMS; FLUID MECHANICS; HYDRAULICS; MECHANICS; REACTOR PROTECTION SYSTEMS; SIMULATION
Optional Information
- Notes
- 3 refs., 1 tab., 5 figs. Imprint:756 refs., 109 tabs., 481 figs.