An engineering top flooding model was developed in MAAP4.04d.4, the severe accident code used in EDF, to simulate the thermal-hydraulic phenomena that should take place if emergency core cooling (ECC) water was injected in hot leg during quenching. In the framework of the ISTC (International Science and Technology Centre), a top flooding test was proposed in the PARAMETER facility (Podolsk, Russia). The MAAP calculation of the PARAMETER top flooding test is presented in this paper. A comparison between top and bottom flooding was made on the bundle test geometry. According to this study, top flooding appears to cool quickly and effectively the upper plenum internals. (author)

Files

38115438.pdf

Files (694.9 kB)

Name Size Download all
md5:bf100a948cc0eb99a95c41c85f852a1b
694.9 kB Preview Download
Part of:
Proceedings of the International Conference Nuclear Energy for New Europe 2006

Additional details

Publishing Information

Publisher
Nuclear Society of Slovenia
Imprint Place
Ljubljana (Slovenia)
ISBN
961-6207-26-3
Imprint Title
Proceedings of the International Conference Nuclear Energy for New Europe 2006
Imprint Pagination
vp.
Journal Page Range
[9 p.]
Report number
INIS-SI--07-002

Conference

Title
International Conference Nuclear Energy for New Europe 2006
Dates
18-21 Sep 2006
Place
Portoroz (Slovenia)

INIS

Country of Publication
Slovenia
Country of Input or Organization
Slovenia
INIS RN
38115438
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ECCS; M CODES; QUENCHING; REACTOR ACCIDENT SIMULATION; TEST FACILITIES; THERMAL HYDRAULICS
Descriptors DEC
COMPUTER CODES; ENGINEERED SAFETY SYSTEMS; FLUID MECHANICS; HYDRAULICS; MECHANICS; REACTOR PROTECTION SYSTEMS; SIMULATION

Optional Information

Notes
3 refs., 1 tab., 5 figs. Imprint:756 refs., 109 tabs., 481 figs.