Implementation of internal monitoring programs for workers occupationally exposed by 131I in nuclear medicine services in Brazil
Creators
- 1. Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Dosimetria
Description
In nuclear medicine services (NMS), workers routinely handle radionuclides for diagnostic and therapy. This practice represents a risk of incorporation by these radionuclides. The International Atomic Energy Agency (IAEA) recommends the implementation of an internal monitoring program on workers exposed to annual effective doses greater than 1 mSv, as for example, those who handle 131I for therapy in NMS. Currently, in Brazil, there are not enough available laboratories qualified to provide internal monitoring services to attend all possible demand of internal monitoring if it such regulation were applied by the Brazilian Nuclear Regulatory Board (CNEN). The objective of this work is to disseminate simple and inexpensive methods for in vivo routine thyroid monitoring of 131I using equipment available in the NMS. Devices available in two public hospitals located in the city of Rio de Janeiro were calibrated for use in occupational internal monitoring. The equipment evaluated in this work presented enough sensitivity for such application, being suitable to access intakes of 131I in the thyroid and able to estimate doses below 1 mSv. (author)
Files
49034160.pdf
Files
(405.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:dc229617faad2bb0d2a8ac89858688e1
|
405.2 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 4 p.
- Report number
- INIS-BR--20111
Conference
- Title
- Goiania 30 years later
- Acronym
- International joint conference RADIO 2017
- Dates
- 25-29 Sep 2017
- Place
- Goiania, GO (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 49034160
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; GAMMA CAMERAS; IN VIVO; IODINE 131; NUCLEAR MEDICINE; OCCUPATIONAL EXPOSURE; PERSONNEL MONITORING; RADIATION DOSES; RADIATION PROTECTION; SENSITIVITY; SURFACE CONTAMINATION MONITORS; THYROID
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CAMERAS; DAYS LIVING RADIOISOTOPES; DOSES; ENDOCRINE GLANDS; GLANDS; INTERMEDIATE MASS NUCLEI; IODINE ISOTOPES; ISOTOPES; MEASURING INSTRUMENTS; MEDICINE; MONITORING; MONITORS; NUCLEI; ODD-EVEN NUCLEI; ORGANS; RADIATION MONITORING; RADIATION MONITORS; RADIOISOTOPES