Published April 1978 | Version v1
Report Restricted

Aseismic design and it's test of multiwalled pipings for an elevated temperature helium gas cooling system

  • 1. Kawasaki Heavy Industries, Ltd., Tokyo

Description

Multiwalled pipings are used for the inpile gas loop, named ''OGL-1'', of which maximum helium gas temperature is 1,0000C. Authors carried out the vibration test of the inpile tube and the multiwalled pipings, and obtained the natural frequencies and damping ratios of which were compared with the design values. It is confirmed that the vibration of the inpile tube is not induced by the cooling water flow. After the vibration test, the multiwalled pipings are analyzed further as single-walled pipings using some assumptions which are included in the effect of the supporting structure. The obtained natural frequencies and vibration modes by analyses coincide with the measured values. The obtained damping ratio of the multiwalled pipings and tube shows the design value 0.5% is very conservative

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Title
Proceedings of the Japan--U.S. seminar on HTGR safety technology. Volume 1. Seismic research
Journal Page Range
p. 234-246.
Report number
BNL-NUREG--50689(Vol.1)

Conference

Title
Seminar on HTGR safety technology.
Dates
15 - 16 Sep 1977.
Place
Upton, NY, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
10441425
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COOLANT LOOPS; HTGR TYPE REACTORS; MECHANICAL VIBRATIONS; REACTOR COOLING SYSTEMS; SEISMIC EFFECTS; SIMULATION
Descriptors DEC
COOLING SYSTEMS; GAS COOLED REACTORS; GRAPHITE MODERATED REACTORS; REACTOR COMPONENTS; REACTORS