Published January 12, 1993 | Version v1
Miscellaneous

ROSA-III/923, BWR Rig of Safety Assessment for LOCA

Description

Description of test facility: ROSA-III is a 1/124 scaled down test facility with electrically heated core designed to study the response of engineered safety features to loss-of-coolant accidents in in commercial BWR. It consists of the following, fully instrumented subsystems: (a) the pressure vessel with a core simulating four half-length fuel assemblies and control rod; (b) steam line and feed water line, which are independent open loops; (c) coolant recirculation system, which consists of two loops provided with a recirculation pump and two jet pumps in each loop; (d) emergency cooling system, including HPCS, LPCS, LPCI, and ADS

Availability note (English)

Available on-line: http://www.nea.fr/abs/html/csni0047.html

Additional details

Publishing Information

Imprint Pagination
[html]

Optional Information

Notes
1 ref.