Grey relevant analysis of sodium critical heat flux in annular channel and the establishing of grey model

Description

Using grey systems theory and experimental data obtained from sodium boiling test loop in China, grey mutual analysis is done to some parameters influencing sodium CHF. The results of CHF are predicted by using GM (1,1) model. The GM(1,h) model is made up for creating CHF model. The results are in good agreement with the experimental data