Published December 1999
| Version v1
Report
Open
Grey relevant analysis of sodium critical heat flux in annular channel and the establishing of grey model
Creators
- 1. Xi'an Jiaotong Univ. (China)
Description
Using grey systems theory and experimental data obtained from sodium boiling test loop in China, grey mutual analysis is done to some parameters influencing sodium CHF. The results of CHF are predicted by using GM (1,1) model. The GM(1,h) model is made up for creating CHF model. The results are in good agreement with the experimental data
Availability note (English)
Available from INIS in electronic formFiles
31045718.pdf
Files
(247.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:79900ac1bcb3e83098dc67dfe3faa7c2
|
247.1 kB | Preview Download |
Additional details
Publishing Information
- ISBN
- 7-5022-2079-8
- Imprint Pagination
- 18 p.
- Report number
- CNIC--01409
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 31045718
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- ANNULAR SPACE; BENCH-SCALE EXPERIMENTS; COOLANT LOOPS; CRITICAL HEAT FLUX; DATA ANALYSIS; LIQUID METALS; MATHEMATICAL MODELS; SODIUM; TEST FACILITIES
- Descriptors DEC
- ALKALI METALS; CONFIGURATION; COOLING SYSTEMS; ELEMENTS; ENERGY SYSTEMS; FLUIDS; HEAT FLUX; LIQUIDS; METALS; SPACE
Optional Information
- Notes
- 4 figs., 8 tabs., 3 refs.
- Secondary number(s)
- XJU--0006