Published June 2002 | Version v1
Journal article

Vibration Measurement By Use Of Noise Analysis In RSG-GAS Reaktor

  • 1. Center for Development of Research Reactor Technology, National Atomic Energy Agency, Serpong (Indonesia)

Description

Vibration measurement have been performed using the signals of the standard reactor instrument of RSG-GAS reactor. Vibration measurement is very important to know the failure in the reactor core and monitoring system. Signals taken from the CIC detector (JKT-03), pressure sensors (JE-01) and IC detector (JAC-01) were then analyzed with domain frequency. Measurement results showed the noise signals of neutron detector JKT-03 CX811 neutron can be seen in the frequency 2,5 Hz caused by reactivity effect around detector. Whoever, the pressure sensors signal can be seen in the JE-01 CP811 and JE-01 CP821 with the frequency of 4 Hz, for JE-01 CP831 in frequency 2,5 Hz and this is due to pressure fluctuation but no vibration for gamma detector IC(JAC-01)

Additional details

Additional titles

Original title (Indonesian)
Pengukuran Vibrasi Dengan Analisis Derau Pada Reaktor RSG-GAS

Publishing Information

Journal Title
Jurnal Teknologi Reaktor Nuklir
Journal Volume
4
Journal Issue
2
Journal Page Range
p. 55-63
ISSN
1411-240X

Optional Information

Notes